Troubleshooting
288 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Action
Retry the firmware update; if not successful, call technical support.
0070 Drive write fault; some data lost
Event Type
Error.
Cause
A SAS or SATA drive reported this error asynchronously. Some data loss
might have occurred if you are using StorSave Performance mode.
Action
Recommend replacing the drive that reported this error.
0080 All RAID keys failed validation
Event Type
Error.
Cause
A RAID key was detected but validation failed or the OEM code is not
correct. Drive detection has been disabled.
Action
Call technical support.